PL.5901 · PL.5902 · 1 L
1 L sterile bottles for PCR, RT-PCR, qPCR, and enzyme reaction setup. Every lot tested for absence of DNase and RNase activity. No DEPC. Factory-direct from Texas.
Manufacturing-grade molecular biology water · per-lot release tested · factory-direct.
DEPC (diethylpyrocarbonate) is the most common chemical treatment for nuclease removal — but DEPC residue is a documented inhibitor of downstream enzyme reactions, especially reverse transcription and in vitro translation. Most autoclave protocols are designed to convert DEPC to ethanol and CO2, but trace residue is a recurring debate in molecular biology literature.
Pro-Lab's process removes nucleases without DEPC — designed for labs running sensitive RT-PCR, qPCR, IVT, or library-prep workflows where residual chemistry could matter.
Every lot is manufactured under controlled conditions and tested to confirm absence of detectable DNase and RNase activity. Testing uses validated enzymatic assays with sensitivity appropriate for trace nuclease detection. Only lots that meet internal release specifications are approved for distribution.
| Spec | Pro-Lab PL.5901/5902 | Thermo Ambion (AM99xx) | Invitrogen UltraPure (10977) | IDT (11-05-01-14) | In-House Milli-Q + DEPC |
|---|---|---|---|---|---|
| DEPC-free | Yes | No (DEPC-treated) | Yes | Yes | Usually DEPC-treated |
| Per-lot release testing | Yes (IFU) | Production-level | Per lot | Per lot | None |
| Pack format | 1 L | 50 mL → 100 mL | 500 mL · 6×500 mL | 50 mL · 1 L | DIY |
| Lot # + expiry on container | Yes | Yes | Yes | Yes | No |
| Factory direct | Yes — Texas | Distributor | Distributor | Yes — Iowa | n/a |
| CoA per lot | On request | Cert Tracker | On request | On request | None |
Competitor data snapshot 2026-05; re-verified quarterly. Public catalogs + datasheets.
PO + Net 30 supported · same-day shipping from Texas · no minimum order. Use the Get Volume Quote button for current prices.
No. Pro-Lab's process removes nucleases without DEPC or other chemical treatments.
Yes — each lot is tested for absence of detectable DNase and RNase activity using validated enzymatic assays before release.
15–30 °C (room temperature), in the original container, tightly closed and protected from contamination.
Yes. This is manufacturing-grade molecular biology water — designed for production-scale PCR / RT-PCR / qPCR, NGS library prep, QC labs, and in-line reagent prep. Every lot is release-tested for DNase and RNase activity; lot number and expiry are printed on every container; CoA is available on request by lot.
CoA is available on request — email support@pro-lab.us with the lot number from your bottle label.
Yes — 6× and 12× case quantities are tiered. Use the Get Volume Quote button.
US shipping is factory-direct from Texas, same-day. For Canada and UK, see pro-lab.com and pro-lab.co.uk respectively.